- I-GEN 3415
- I-GEN 5415
- I-GEN 7415
- I-GEN 10415
- I-GEN 15415
- I-GEN 20415
- I-GEN 25415
- I-GEN 30415
- I-GEN 40415
- I-GEN 50415
- I-GEN 100415
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 3415 | |
Image | ||
Power rating | 3 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 6-10 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 5415 | |
Image | ||
Power rating | 5 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 8-13 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 7415 | |
Image | ||
Power rating | 7.5 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 12-16 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 10415 | |
Image | ||
Power rating | 10 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 16-24 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 15415 | |
Image | ||
Power rating | 15 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 24-34 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 20415 | |
Image | ||
Power rating | 20 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 32-46 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 25415 | |
Image | ||
Power rating | 25 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 40-56 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 30415 | |
Image | ||
Power rating | 30 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 48-67 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 40415 | |
Image | ||
Power rating | 40 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 64-88 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 50415 | |
Image | ||
Power rating | 50 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 80-110 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
2 or 3 phase input- 3 phase output with optional Solar access (only motor loads can be used in this model) | ||
MODEL NO | I-GEN 100415 | |
Image | ||
Power rating | 100 HP | |
AC input | 2/3 Phase | |
AC input voltage p-p | 240-490 V | |
AC Output volatge 3 phase | 380-440 V | |
Output current I out per Phase | 160-200 A | |
Output Frequency | 0-50 Hz | |
Output THD | ≤5 % | |
Ambient temperature | 45oC | |
Enclosure type | IP 25 | |
Cooling system Natural | Fan | |
Effective Pumping hours on AC | 24 | |
Solar Options | Contains built in MPPT, Solar power can be connected directly to the optimizer Upto the capacity 1.5 times equal to that of unit size. Also it can share grid supply in the input | |
Pump selection | Any 3 phase 380-440 v pump with RYB can be used | |
Protection | Reverse polarity, Over load, Under load Short circuit, High current, High voltage, High temperature, Lightening and Dry run (sensor less) |
Contact Us
Chennai (Regd Office) :
Flat No.24, Paramount Apartment, 39C, North Parade Road, St.Thomas Mount, Chennai-600016.
18008890045
+91 94447 89013
sahayalouis@deltastarsustainableproducts.com
enquiry@dsnetzero.com
Dindigul (Factory) :
SF no 416/11 Soosai Patty - MDR 904
Coimbatore :
H6, TNHB Colony, Rajiv Gandhi Nagar, Sowripalayam PO, Coimbatore-28.
Oman :
Delta solar Company LLC,
PO 2571, PC 130 Al Aziba, Oman.
© Copyright 2024 Delta Star Solar Energy Pvt Ltd.