- Hydro HD2415
- Hydro HD3415
- Hydro HD5415
- Hydro HD7415
- Hydro HD10415
- Hydro HD15415
TECHNICAL SPECIFICATION 415 V AC 3 PHASE OUT PUT | ||
MODEL NO | Hydro HD2415 | |
Image | ||
Power rating | 2 HP | |
Input voltage Voc | 450-750 V | |
Input current I max. | 8A | |
Wattage Pv required | 1500-2400 | |
Output voltage V ac 3 phase | 415 | |
Output Frequency | 0-60Hz | |
Best water flow @ Frequency | 40-50 Hz | |
MPPT Tracking efficiency | > 98 % | |
Ambient temperature | 450C | |
Head range in Mts. | UNLIMITED | |
Enclosure type | IP 55 | |
Cooling system Natural | Convection | |
Effective Pumping hours | 7-9 | |
Pump selection | Any 3 phase pump | |
Display - 4 line LCD | Pv aray volt, current, wattage, frequency,Output voltage | |
Protection | Reverse polarity, short circuit, over current, over voltage, Lightening, Dry run (sensor less) | |
Data collection | RS484 port for instant data collection and can be accessed via net work- Optional |
TECHNICAL SPECIFICATION 415 V AC 3 PHASE OUT PUT | ||
MODEL NO | Hydro HD3415 | |
Image | ||
Power rating | 3 HP | |
Input voltage Voc | 450-750 V | |
Input current I max. | 8A | |
Wattage Pv required | 2250-3600 | |
Output voltage V ac 3 phase | 415 | |
Output Frequency | 0-60Hz | |
Best water flow @ Frequency | 40-50 Hz | |
MPPT Tracking efficiency | > 98 % | |
Ambient temperature | 450C | |
Head range in Mts. | UNLIMITED | |
Enclosure type | IP 55 | |
Cooling system Natural | Convection | |
Effective Pumping hours | 7-9 | |
Pump selection | Any 3 phase pump | |
Display - 4 line LCD | Pv aray volt, current, wattage, frequency,Output voltage | |
Protection | Reverse polarity, short circuit, over current, over voltage, Lightening, Dry run (sensor less) | |
Data collection | RS484 port for instant data collection and can be accessed via net work- Optional |
TECHNICAL SPECIFICATION 415 V AC 3 PHASE OUT PUT | ||
MODEL NO | Hydro HD5415 | |
Image | ||
Power rating | 5 HP | |
Input voltage Voc | 450-750 V | |
Input current I max. | 8A | |
Wattage Pv required | 3500-6000 | |
Output voltage V ac 3 phase | 415 | |
Output Frequency | 0-60Hz | |
Best water flow @ Frequency | 40-50 Hz | |
MPPT Tracking efficiency | > 98 % | |
Ambient temperature | 450C | |
Head range in Mts. | UNLIMITED | |
Enclosure type | IP 55 | |
Cooling system Natural | Convection | |
Effective Pumping hours | 7-9 | |
Pump selection | Any 3 phase pump | |
Display - 4 line LCD | Pv aray volt, current, wattage, frequency,Output voltage | |
Protection | Reverse polarity, short circuit, over current, over voltage, Lightening, Dry run (sensor less) | |
Data collection | RS484 port for instant data collection and can be accessed via net work- Optional |
TECHNICAL SPECIFICATION 415 V AC 3 PHASE OUT PUT | ||
MODEL NO | Hydro HD7415 | |
Image | ||
Power rating | 7.5 HP | |
Input voltage Voc | 450-750 V | |
Input current I max. | 16A | |
Wattage Pv required | 5600-9400 | |
Output voltage V ac 3 phase | 415 | |
Output Frequency | 0-60Hz | |
Best water flow @ Frequency | 40-50 Hz | |
MPPT Tracking efficiency | > 98 % | |
Ambient temperature | 450C | |
Head range in Mts. | UNLIMITED | |
Enclosure type | IP 55 | |
Cooling system Natural | Convection | |
Effective Pumping hours | 7-9 | |
Pump selection | Any 3 phase pump | |
Display - 4 line LCD | Pv aray volt, current, wattage, frequency,Output voltage | |
Protection | Reverse polarity, short circuit, over current, over voltage, Lightening, Dry run (sensor less) | |
Data collection | RS484 port for instant data collection and can be accessed via net work- Optional |
TECHNICAL SPECIFICATION 415 V AC 3 PHASE OUT PUT | ||
MODEL NO | Hydro HD10415 | |
Image | ||
Power rating | 10 HP | |
Input voltage Voc | 450-750 V | |
Input current I max. | 16A | |
Wattage Pv required | 7500-12000 | |
Output voltage V ac 3 phase | 415 | |
Output Frequency | 0-60Hz | |
Best water flow @ Frequency | 40-50 Hz | |
MPPT Tracking efficiency | > 98 % | |
Ambient temperature | 450C | |
Head range in Mts. | UNLIMITED | |
Enclosure type | IP 55 | |
Cooling system Natural | Convection | |
Effective Pumping hours | 7-9 | |
Pump selection | Any 3 phase pump | |
Display - 4 line LCD | Pv aray volt, current, wattage, frequency,Output voltage | |
Protection | Reverse polarity, short circuit, over current, over voltage, Lightening, Dry run (sensor less) | |
Data collection | RS484 port for instant data collection and can be accessed via net work- Optional |
TECHNICAL SPECIFICATION 415 V AC 3 PHASE OUT PUT | ||
MODEL NO | Hydro HD15415 | |
Image | ||
Power rating | 15 HP | |
Input voltage Voc | 450-750 V | |
Input current I max. | 16A | |
Wattage Pv required | 11250-18750 | |
Output voltage V ac 3 phase | 415 | |
Output Frequency | 0-60Hz | |
Best water flow @ Frequency | 40-50 Hz | |
MPPT Tracking efficiency | > 98 % | |
Ambient temperature | 450C | |
Head range in Mts. | UNLIMITED | |
Enclosure type | IP 55 | |
Cooling system Natural | Convection | |
Effective Pumping hours | 7-9 | |
Pump selection | Any 3 phase pump | |
Display - 4 line LCD | Pv aray volt, current, wattage, frequency,Output voltage | |
Protection | Reverse polarity, short circuit, over current, over voltage, Lightening, Dry run (sensor less) | |
Data collection | RS484 port for instant data collection and can be accessed via net work- Optional |
Contact Us
Chennai (Regd Office) :
Flat No.24, Paramount Apartment, 39C, North Parade Road, St.Thomas Mount, Chennai-600016.
18008890045
+91 94447 89013
sahayalouis@deltastarsustainableproducts.com
enquiry@dsnetzero.com
Dindigul (Factory) :
SF no 416/11 Soosai Patty - MDR 904
Coimbatore :
H6, TNHB Colony, Rajiv Gandhi Nagar, Sowripalayam PO, Coimbatore-28.
Oman :
Delta solar Company LLC,
PO 2571, PC 130 Al Aziba, Oman.
© Copyright 2024 Delta Star Solar Energy Pvt Ltd.
Website by OCS