Phase Optimizer with Dedicated Neutral

  • O-GEN 05415
  • O-GEN 10415
  • O-GEN 15415
  • O-GEN 20415
  • O-GEN 25415
  • O-GEN 30415
  • O-GEN 40415
  • O-GEN 50415
  • O-GEN 60415
  • O-GEN 75415
  • O-GEN 100415
  • O-GEN 125415
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 05415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 5KVA
Output rated current (A) 7A
Input current (A) 11 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 10415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 10KVA
Output rated current (A) 14A
Input current (A) 21 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 15415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 15 KVA
Output rated current (A) 20 A
Input current (A) 30 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 20415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 20 KVA
Output rated current (A) 28 A
Input current (A) 42 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 25415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 25 KVA
Output rated current (A) 36 A
Input current (A) 52 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 30415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 30 KVA
Output rated current (A) 40 A
Input current (A) 60 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 40415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 40 KVA
Output rated current (A) 56 A
Input current (A) 84 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 50415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 50 KVA
Output rated current (A) 70 A
Input current (A) 105 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 60415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 60 KVA
Output rated current (A) 90 A
Input current (A) 135 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 75415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 75 KVA
Output rated current (A) 105 A
Input current (A) 157 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 100415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 100 KVA
Output rated current (A) 140 A
Input current (A) 210 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Price
Technical Specifications of Phase Optimizer (2-3 Phase Convertor) with Dedicated Neutral
MODEL NO O-GEN 125415
Image
Input rated voltage 415Vac /50Hz Three phase/350-480 Vac Two Phase
Input range voltage normal model 300-480 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input range voltage custom model 200-530 Vac/50 Hz Two Phase/Three phase (Phase to Phase)
Input Frequency 50HZ ± 0.05Hz
Rated AC output power 125 KVA
Output rated current (A) 185 A
Input current (A) 277 A
AC output waveform Pure sine wave
Output Phases Three phase, 4 wires (R Y B N )
Output voltage 380-440vac /50Hz
Power Factor(PF) 0.95
Efficiency >97%
Ambient temperature -15 T0 55°C
Cooling method Fan-cooled
Degree of protection IP30(indoor)
Monitoring facility LED DISPLAY FOR Digital voltage meter: 0.1V Digital current meter: 0.1A INPUT & OUTPUT INDICATION LAMP
Dimensions (mm) Approx 1000mm * 800mm * 1200mm ( W * D * H )50, 100 & 125KVA     800mm * 600mm * 900mm ( W * D * H ) 20,30,40 KVA
Weight(Kg)Approx 220KGS ( 20KVA ) 250 KGS (30KVA) 380 KGS (50KVA) 440 KGS (60KVA) 590 KGS (100KVA)
Battery Options 30 nos. of battery can be connected in series to create 360 V DC input. The battery charging current can be controllerd with charge controller MPPT.
Contact Us

Chennai (Regd Office) :

Flat No.24, Paramount Apartment, 39C, North Parade Road, St.Thomas Mount, Chennai-600016.

18008890045
+91 94447 89013
sahayalouis@deltastarsustainableproducts.com
enquiry@dsnetzero.com

Dindigul (Factory) :

SF no 416/11 Soosai Patty - MDR 904

Coimbatore :

H6, TNHB Colony, Rajiv Gandhi Nagar, Sowripalayam PO, Coimbatore-28.

Oman :

Delta solar Company LLC,
PO 2571, PC 130 Al Aziba, Oman.